Huawei's next-generation NetEngine AR600 series enterprise routers use multi-core processors and a non-blocking switching structure, helping to deliver three times the industry average performance. The NetEngine AR600 also integrates functions such as SD-WAN, cloud management, routing, switching, VPN, WLAN, and security, ensuring diversified and cloud-based services are fully supported.
Quick Specs
Table 1 shows the Quick Specs.
Product Code |
AR611W-S |
CPU |
1.1 GHz, 2 Cores |
Memory |
1 GB |
NAND Flash |
1 GB |
Console port |
RJ45 |
RTC |
Supported |
Maximum power consumption [W] |
12 W |
Compare to Similar Items
Table 2 shows the comparison.
Item |
NetEngine AR611 |
NetEngine AR611W |
NetEngine AR617VW |
NetEngine AR617VW-LTE4EA/AR617VW-LTE4 |
Wi-Fi |
- |
Dual-band (2.4 GHz and 5 GHz), 2x2 MIMO, 802.11b/g/n/ac |
||
Auxiliary or console port |
1 x RJ45 console port |
|||
USB port |
1*USB2.0 |
1*USB2.0 |
1*USB2.0 |
1*USB2.0 |
Memory |
1GB |
1GB |
1GB |
1GB |
Flash memory |
1GB |
1GB |
1GB |
1GB |
Maximum output current (AC) |
2A |
2A |
2A |
2A |
Maximum output power (AC) |
24W |
24W |
24W |
24W |
Minimum power consumption |
4W |
7W |
8W |
8W |
Maximum power consumption |
5W |
12W |
15W |
17W |
AR611W-S Specification
AR611W-S Specification |
|
Item |
Specification |
Installation type |
|
Dimensions without packaging (H x W x D) [mm(in.)] |
|
Dimensions with packaging (H x W x D) [mm(in.)] |
90 mm x 370 mm x 297 mm (3.54 in. x 14.57 in. x 11.69 in.) |
CPU |
1.1 GHz, 2 Cores |
Memory |
1 GB |
NAND Flash |
1 GB |
Console port |
RJ45 |
RTC |
Supported |
Maximum power consumption [W] |
12 W |
Power supply mode |
AC external |
Number of power modules |
1 |
Rated input voltage [V] |
100 V to 240 V, 50 Hz/60 Hz |
Input voltage range [V] |
90 V to 270 V, 45 Hz to 65 Hz |
Maximum input current [A] |
0.8 A |
Maximum output power [W] |
24 W |
Type of fans |
None |
Number of fan modules |
0 |
Heat dissipation mode |
Natural heat dissipation |
Redundant power supply |
Not supported |
PoE |
Not supported |
Noise at normal temperature (acoustic power) [dB(A)] |
0 (Natural heat dissipation) |
Long-term operating temperature [°C(°F)] |
0°C to 40°C (32°F to 104°F) NOTE: When the altitude is 1800 m-5000 m (5906 ft.-16404.2 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). |
Storage temperature [°C(°F)] |
-40°C to +70°C (-40°F to +158°F) |
Long-term operating relative humidity [RH] |
5% to 95%, noncondensing |
Long-term operating altitude [m(ft.)] |
< 5000 m (16404.2 ft.) |